We are independent & ad-supported. We may earn a commission for purchases made through our links.
Advertiser Disclosure
Our website is an independent, advertising-supported platform. We provide our content free of charge to our readers, and to keep it that way, we rely on revenue generated through advertisements and affiliate partnerships. This means that when you click on certain links on our site and make a purchase, we may earn a commission. Learn more.
How We Make Money
We sustain our operations through affiliate commissions and advertising. If you click on an affiliate link and make a purchase, we may receive a commission from the merchant at no additional cost to you. We also display advertisements on our website, which help generate revenue to support our work and keep our content free for readers. Our editorial team operates independently of our advertising and affiliate partnerships to ensure that our content remains unbiased and focused on providing you with the best information and recommendations based on thorough research and honest evaluations. To remain transparent, we’ve provided a list of our current affiliate partners here.
Electrical

Our Promise to you

Founded in 2002, our company has been a trusted resource for readers seeking informative and engaging content. Our dedication to quality remains unwavering—and will never change. We follow a strict editorial policy, ensuring that our content is authored by highly qualified professionals and edited by subject matter experts. This guarantees that everything we publish is objective, accurate, and trustworthy.

Over the years, we've refined our approach to cover a wide range of topics, providing readers with reliable and practical advice to enhance their knowledge and skills. That's why millions of readers turn to us each year. Join us in celebrating the joy of learning, guided by standards you can trust.

What are Auxiliary Contacts?

By Paul Scott
Updated: May 17, 2024
Views: 113,877
Share

Auxiliary contacts are secondary switching devices that work in conjunction with primary switching equipment such as circuit breakers, relays, and contactors. These contacts are physically linked to the main switching mechanism and activate at the same time it does. They are commonly used as interlocks or retainers on the primary device's control circuit and often used to give indication of its state of operation. Many contactors and circuit breakers feature sets of auxiliary contacts as integral parts or they may be modular snap on units which can be added or removed as required. They are available with either normally open or normally closed contact points or a combination of both.

Main circuit switching devices, such as circuit breakers and contactors, often require additional switching functions over and above those of their primary contacts. These include remote indication of their status, trip function indication, electrical interlocks, and start circuit retainers. These functions have no physical bearing on the main circuit and stand alone. In addition, the voltage used for these auxiliary circuits will typically be far lower than that of the main circuit. To achieve this simultaneous yet separate switching, auxiliary contact points activate along with the primary device. These are generally a lot smaller and rated at lower current values than those of the main device.

One of the main uses of auxiliary contacts is the electrical retainer circuit. This is a control circuit function that allows the use of momentary, push type buttons to start motors and other equipment. Another common function of these contacts is remote status and trip indication. A separate, low voltage circuit is run through the auxiliary to a remote indication lamp that illuminates when the device is activated or trips. Auxiliary contact points may also be used to switch on ancillary equipment, such as starter panel cooling fans, when the contactor activates.

There are two basic auxiliary contact types: those that are closed in the non-activated state or those that are open. These are known as normally closed (N/C) and normally open (N/O) contacts. The N/C contacts are, for example, used as electrical interlocks where two contactors are used for forward/reverse operation. The control circuit for one contactor will run through the N/C auxiliary on the other. This means that one cannot be inadvertently started while the other is operating. The N/O contacts are generally used to switch on status indication lamps and act as retainer circuits.

Many circuit breakers and contactors have auxiliary contacts built in as an integral feature. Additional sets of contacts may, however, be added should the need arise. These modules typically slide on the top of smaller relays or snap onto the existing auxiliary set.

Share
About Mechanics is dedicated to providing accurate and trustworthy information. We carefully select reputable sources and employ a rigorous fact-checking process to maintain the highest standards. To learn more about our commitment to accuracy, read our editorial process.
Discussion Comments
Share
https://www.aboutmechanics.com/what-are-auxiliary-contacts.htm
Copy this link
About Mechanics, in your inbox

Our latest articles, guides, and more, delivered daily.

About Mechanics, in your inbox

Our latest articles, guides, and more, delivered daily.